- These load cells are extremely Slim and lightweight.
- Easy installation with hole in center.
- Designed for use in civil engineering measurement, these loads on tunnel supports and soil pressure on protective Walls to aid control in construction projects.
- Protection Class IP67
Specifications
Specifications | Accuracy |
---|---|
Rated capacity(R.C) | 50kgf, 100kgf, 200kgf, 500kgf, 1tf, 2tf, 3tf, 5tf,10tf, 20tf, 30tf, 50tf, 100tf, 150tf, 200tf (490.3N, 980.7N, 1.961kN, 4.903kN, 9.807kN, 19.61kN, 29.42kN, 49.03kN, 98.07kN, 196.1kN, 490.3kN, 980.7kN, 1.961MN) |
Rated output(R.O) | 1.5mV/V±0.4% |
Nonlinearity | 1% of R.O. |
Hysteresis | 0.5% of R.O. |
Repeatability | 0.5% of R.O. |
Zero balance | 0.5% of R.O. |
Terminal resistance input | 700 ±10Ω |
Terminal resistance output | 700 ±5Ω |
Insulation resistance | 2000Ω |
Temperature range, compensated | -10~60℃ |
Temperature range, Safe | -20~80℃ |
Temperature effect, on zero balance | 0.1% R.O./10℃ |
Temperature effect, on rated output | 0.05% R.O./10℃ |
Excitation recommended | 10V |
Safe overload | 150% R.C |
Cable length | Φ7mm 4core, 3m |
Dimensions Table
Capacity | ΦA | ΦB | ΦC | D | E | Weight (kg) |
---|---|---|---|---|---|---|
50kgf (490.3N) | 10 | 55 | 22 | 15 | 2 | 2 |
100kgf (980.7N) | 10 | 55 | 22 | 15 | 2 | |
200kgf (1.961kN) | 10 | 55 | 22 | 15 | 2 | |
500kgf (4.903kN) | 10 | 55 | 22 | 15 | 2 | |
1tf (9.807kN) | 12 | 68 | 28 | 20 | 1.5 | 2.5 |
2tf (19.61kN) | 12 | 68 | 28 | 20 | 1.5 | |
3tf (29.42kN) | 12 | 68 | 28 | 20 | 1.5 | |
5tf (49.03kN) | 12 | 68 | 28 | 20 | 1.5 | |
10tf (98.07kN) | 50 | 148 | 80 | 37 | 5 | 3 |
20tf (196.1kN) | 70 | 155 | 99 | 43 | 5 | 6 |
30tf (294.2kN) | 70 | 155 | 99 | 43 | 5 | |
50tf (490.3kN) | 70 | 155 | 99 | 43 | 5 | |
100tf (980.7kN) | 110 | 198 | 129 | 43 | 5 | 8 |
150tf (1.471MN) | 165 | 278 | 200 | 50 | 8 | 20 |
200tf (1.961MN) | 170 | 308 | 212 | 65 | 10 | 27 |